Signs Your Watch Is Magnetized and How to Fix It
Your mechanical watch used to gain just a few seconds per day, but now it suddenly gains several minutes all at once. You may wonder if the movement is damaged, or if you have made an operational error, and another possibility is that the watch has been magnetized — though this is not necessarily the root cause.
New watch enthusiasts may have never heard of "watch magnetisation" and have no idea what it means, while even those who have heard of the term rarely have a solid understanding of it. Many watch enthusiasts notice that their timepieces are not keeping accurate time and assume it is caused by improper operation on their part, believing that simply calibrating the watch will fix the issue. However, the reality is often far more complicated than that.
This guide will explain what watch magnetisation is, how to demagnetise an automatic mechanical watch safely, and how to prevent a watch from becoming magnetized, in the hope that it can help fellow watch enthusiasts who are worried about this issue.
Common Symptoms of a Magnetized Watch
The most obvious symptom of a Magnetized watch is a sudden change in its rate of timekeeping. If the time deviation of your watch is small and stable, that is normal; however, if a watch that previously kept accurate time suddenly shows a significant deviation, you need to have it checked.
Your Watch Suddenly Runs Much Faster
Your watch usually gains 5 seconds per day, but now it gains 3 minutes daily. This is a noticeable change, most likely caused by exposure to a magnetic field.
However, it is not possible to confirm that the watch has been magnetized solely based on its timekeeping error.
The Timekeeping Becomes Less Consistent
Not every watch with a possible magnetism problem runs fast at the same rate each day. You might notice it gaining several minutes one day, then showing a different error the next.
What's worth paying attention to is the change from its usual behaviour. A watch that consistently gains a few seconds each day is one thing. A watch that suddenly starts showing large, unpredictable differences is another.
Your Watch Runs Slow, Erratically, or Stops
Your watch starts running slow or stops for no apparent reason. You might suspect it’s magnetized, but there are other factors to check.
When did you last wear or wind your watch? If it's been sitting unused for a while, it may have run out of power.
Rule Out Other Watch Problems First
A sudden change in timekeeping can have several causes. Please first confirm whether the time error is within the normal accuracy range of the watch and rule out other possible causes.
| Possible cause | What to look for | What to do |
|---|---|---|
| Normal daily variation | Small, steady gain or loss | Compare with the manufacturer's accuracy range |
| Low power | Watch slows, runs unevenly, or stops after being left unused | Wind it according to the manufacturer's instructions and check again |
| Impact damage | Timing changes after a drop or hard knock; hands or functions behave abnormally | Have a watchmaker inspect it |
| Water or moisture | Fog under crystal or known water exposure | Seek professional service promptly |
| Movement fault | Timing problems continue despite adequate power or after demagnetising | Have the movement checked by a watchmaker |
If none of these problems seems to explain the sudden timing change, checking for magnetism is a reasonable next step.
How to Tell If Your Watch Is Magnetized at Home
You can check for signs of magnetism at home, but you can't tell for sure whether your watch is magnetized.
Check How Fast or Slow Your Watch Runs
Wind your watch as the manufacturer recommends, then set it using a reliable clock.
See how much time your watch has gained or lost after 24 hours. Do the same over the next few days, and compare the results with the manufacturer's accuracy range.
If your watch used to gain just a few seconds a day but now runs several minutes fast, magnetism could be the cause. Other problems can affect its timing too.
Check for Recent Magnetic Exposure
Think about where you've had it lately. It may have been near something magnetic without you knowing it.
Ask yourself:
- Was the watch near a magnetic phone case?
- Did you place it beside a wireless charger?
- Was it close to a speaker or earbud case?
- Did it touch a tablet cover or bag clasp?
- Was it near a magnetic tool?
If your watch starts running abnormally after being close to the items listed above, it may have been magnetized.
Why Compass and Phone Tests Are Unreliable
The metal case will affect the Compass and the phone's magnetometer. When magnetic components in the watch case, strap, or buckle are close to the Compass, the Compass may deflect; if a phone is placed near the watch, the magnetometer app on the phone will also show abnormal readings.
Therefore, the Compass and mobile phone magnetometers cannot confirm whether there is magnetism inside the movement.
Do not open the case
Do not open the watch case when detecting magnetism or using a demagnetizer. Opening the case may allow dust to get inside, damage the movement, and even affect the water resistance of the watch.
If you are still unsure about the cause of your watch being magnetized, you can ask a watchmaker to measure how much your watch is running fast or slow, or use other equipment to check whether it is magnetized.
How to Demagnetise a Watch Safely
Only attempt to demagnetize your watch by yourself if it only has a simple magnetization issue. If any of the aforementioned potential magnetization scenarios apply, do not attempt self-demagnetisation and seek professional assistance instead. If your watch is valuable or you are not familiar with the operation of the equipment you are using, it is more reliable to have it handled by a professional.
Record the error first
Set the watch against a reliable time source. Record how much it gains or loses over a fixed period.
Also note:
- How much you wound it
- How long you wore it
- Where you placed it overnight
- How long you observed it
This makes the before-and-after comparison more useful.
Read the device instructions
Do not copy a video made for another demagnetiser.
Check:
- Where to place the watch
- How to start the device
- How long to run it
- Whether the watch should move
- When to switch the device off
Different devices may use different steps. The following procedure applies only to the Antimag 2. Do not use the Antimag 2 to demagnetise an electronic watch.
Follow the exact process
Keep the watch closed. For the Antimag 2, place the watch on the surface of the device. Press and hold the activation switch for about three seconds, then release it. Demagnetising occurs when the switch is released.
Do not touch, pull, or adjust the hairspring. For any other demagnetiser, follow that device’s official instructions for placement, movement, and shut-off order.
After following the device-specific process once, check the result. Do not repeat it without a clear reason.
A demagnetiser cannot fix a bent hairspring, poorly lubricated or worn movement parts, impact damage, or water inside the case.
Check the Result and Know When to Seek Service
Keep the test conditions similar before and after demagnetising.
Try to match the:
- Winding level
- Wearing time
- Overnight position
- Observation period
Compare the watch with a reliable time source. Record the start and end times, then check the result against your brand’s official specifications.
If the watch was gaining several minutes a day and returns close to its old, steady rate, magnetism may have been the main cause. Keep checking it for a few more days.
If there is no clear improvement, stop repeating the process.
Seek professional help if any of the magnetic exposure scenarios mentioned, if the watch keeps gaining or losing a lot of time, if its power reserve becomes much shorter, or if demagnetising brings no clear improvement.
Bring your notes to the watchmaker. Include when the problem began, possible magnetic exposure, demagnetiser use, and the timing results before and after.
Avoid Magnetism and Do Not Blame Every Watch Winder
Keep your watch away from direct contact with:
- Magnetic phone accessories
- Wireless chargers
- Speakers
- Earbud cases
- Tablet covers
- Bag clasps
- Magnetic tools
A fixed storage spot helps too. Keep the watch away from charging areas, speakers, and bags with magnetic closures.
MOZSLY’s current product pages for the VISTRA Single and Black Knight Double state that their winding mechanisms will not magnetise a watch and cite internal magnetic-flux measurements. This is model-specific product-page evidence; not every watch winder works the same way.
If you're concerned about magnetism or wear, learn more about whether a watch winder can damage your watch.
If the problem appears only after using one device, stop using it for a few days. Compare the watch’s timing before and after use under similar conditions.
If you use a Mozsly watch winder, check the exact model’s instructions, warranty, operating conditions, and watch compatibility. Its wonderful design can make watch storage easier, but every device still deserves a basic check.
FAQ About Watch Magnetism
Yes. A mechanical watch can remain magnetized even after it is moved away from the magnetic source. That is one reason its timing may continue to be inaccurate after the original exposure has ended. If the watch keeps gaining or losing unusual amounts of time after it has been moved away from magnetic objects, it may need to be checked or demagnetized.
There is no single distance that covers every magnet or electronic device because magnetic-field strength varies. As a practical precaution, avoid placing a mechanical watch directly against magnetic phone accessories, speakers, charging equipment, or magnetic closures. If a manufacturer gives a specific minimum distance for your watch or the nearby device, follow that guidance.
Yes. A mechanical watch can gain or lose time because of temperature, its resting position, the amount of power stored in the mainspring, and normal wearing conditions. That means a change in accuracy does not automatically point to magnetism. Compare the watch over several days under similar conditions before deciding that something is wrong.
Usually not. One day can give you a useful clue, but mechanical-watch accuracy can vary from day to day. For a more useful comparison, observe the watch over several days while keeping the winding level, wearing time, and overnight position as consistent as possible. Then compare the overall pattern with the manufacturer’s stated accuracy range.
No. Mechanical and quartz watches do not always react to magnetic fields in the same way. A mechanical movement may remain magnetized after exposure and continue gaining or losing time. Some quartz watches may behave differently around strong magnetic fields, so always check the instructions for your specific watch before assuming the same diagnosis or fix applies to every movement type.
Conclusion: Test, demagnetise, Then Check Again
A watch that was stable and suddenly runs several minutes fast may be magnetized.
You now know what to check, what not to assume, and when to stop testing. Start by checking the power level and looking for signs of impact or water. Then, if the watch only shows possible magnetic symptoms, follow the instructions for your specific demagnetiser and record the result.
If the timing does not improve, do not keep guessing. Contact a watchmaker, the brand’s service team, or a reliable repair centre.
Your next step is simple: check the symptoms, record the error, and choose the safest option. If this guide helped, save it or share it with another watch owner.